<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	
	>
<channel>
	<title>
	Comments on: Is It Okay To Use Pecos Code 075?	</title>
	<atom:link href="https://blog.model-train-help.com/2020/07/5694.html/feed" rel="self" type="application/rss+xml" />
	<link>https://blog.model-train-help.com/2020/07/5694.html?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=5694</link>
	<description>Model railroads and model trains</description>
	<lastBuildDate>Thu, 23 Jul 2020 02:59:40 +0000</lastBuildDate>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>
	<item>
		<title>
		By: Nigel d Woodgate		</title>
		<link>https://blog.model-train-help.com/2020/07/5694.html#comment-39434</link>

		<dc:creator><![CDATA[Nigel d Woodgate]]></dc:creator>
		<pubDate>Thu, 23 Jul 2020 02:59:40 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=5694#comment-39434</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://blog.model-train-help.com/2020/07/5694.html#comment-39376&quot;&gt;Chris Hughes&lt;/a&gt;.

I have bought four Peco code 075 double/single slip crossings-{Electrofrog} seen youtube and thy say as long you have a code 075/100 section, this will be OK.. for either both old and new rolling stock-i.e-locomotives! So will this be OK.. 
I do have a Pecos code 100 long crossing-{Insulfrog} crossing]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://blog.model-train-help.com/2020/07/5694.html#comment-39376">Chris Hughes</a>.</p>
<p>I have bought four Peco code 075 double/single slip crossings-{Electrofrog} seen youtube and thy say as long you have a code 075/100 section, this will be OK.. for either both old and new rolling stock-i.e-locomotives! So will this be OK..<br />
I do have a Pecos code 100 long crossing-{Insulfrog} crossing</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Chris Hughes		</title>
		<link>https://blog.model-train-help.com/2020/07/5694.html#comment-39376</link>

		<dc:creator><![CDATA[Chris Hughes]]></dc:creator>
		<pubDate>Fri, 17 Jul 2020 16:05:43 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=5694#comment-39376</guid>

					<description><![CDATA[Peco make special rail joiners for mating code 100 with code 75 however I would not recommend using code 75 track with older deep flanged stock as it will ride the chairs and give erratic running. Also the flanges on older stock are too wide to go through points and turnout check rails so you need to stick with code 100 if you intend running old ( say pre 1980) stock]]></description>
			<content:encoded><![CDATA[<p>Peco make special rail joiners for mating code 100 with code 75 however I would not recommend using code 75 track with older deep flanged stock as it will ride the chairs and give erratic running. Also the flanges on older stock are too wide to go through points and turnout check rails so you need to stick with code 100 if you intend running old ( say pre 1980) stock</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Geoff		</title>
		<link>https://blog.model-train-help.com/2020/07/5694.html#comment-39355</link>

		<dc:creator><![CDATA[Geoff]]></dc:creator>
		<pubDate>Thu, 16 Jul 2020 17:00:22 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=5694#comment-39355</guid>

					<description><![CDATA[As Phil says, you will likely have problems.  Maybe not derailments, but locomotives won&#039;t make contact with the rail, so no power, and the wheels may get stuck on the crossings.  But since you have some code 075 crossings the best way is to lay a small piece of test track and try it out.  One other difficulty may be with the join between the two types of rail, since they are different sizes. And maybe the sleepers / ties are different heights.]]></description>
			<content:encoded><![CDATA[<p>As Phil says, you will likely have problems.  Maybe not derailments, but locomotives won&#8217;t make contact with the rail, so no power, and the wheels may get stuck on the crossings.  But since you have some code 075 crossings the best way is to lay a small piece of test track and try it out.  One other difficulty may be with the join between the two types of rail, since they are different sizes. And maybe the sleepers / ties are different heights.</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: phil johnson		</title>
		<link>https://blog.model-train-help.com/2020/07/5694.html#comment-39342</link>

		<dc:creator><![CDATA[phil johnson]]></dc:creator>
		<pubDate>Thu, 16 Jul 2020 05:27:41 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=5694#comment-39342</guid>

					<description><![CDATA[If you have equipment with deep flanges, they will not work on code 70/75.  I have a old Fleischmann 2-10-0 given to me by a close friend.  It will run on code 100 but very erratic on code 83 with hand laid rail.  Laughs at me when I placed it on both commercial and hand laid track]]></description>
			<content:encoded><![CDATA[<p>If you have equipment with deep flanges, they will not work on code 70/75.  I have a old Fleischmann 2-10-0 given to me by a close friend.  It will run on code 100 but very erratic on code 83 with hand laid rail.  Laughs at me when I placed it on both commercial and hand laid track</p>