<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	
	>
<channel>
	<title>
	Comments on: Broadway  GE ES44AC	</title>
	<atom:link href="https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html/feed" rel="self" type="application/rss+xml" />
	<link>https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=broadway-ge-es44ac</link>
	<description>Model railroads and model trains</description>
	<lastBuildDate>Wed, 22 Dec 2021 16:21:48 +0000</lastBuildDate>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>
	<item>
		<title>
		By: Frank		</title>
		<link>https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55888</link>

		<dc:creator><![CDATA[Frank]]></dc:creator>
		<pubDate>Wed, 22 Dec 2021 16:21:48 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=6366#comment-55888</guid>

					<description><![CDATA[BLIs are known for having decoder issues similar to this.  If you try all the appropriate checks and steps to insure it&#039;s not your layout to no avail, then contact BLI.  I&#039;ve not had to interact with their customer support, but others have said their better than average.  You may have to send it in to them or they may just send you a replacement decoder.]]></description>
			<content:encoded><![CDATA[<p>BLIs are known for having decoder issues similar to this.  If you try all the appropriate checks and steps to insure it&#8217;s not your layout to no avail, then contact BLI.  I&#8217;ve not had to interact with their customer support, but others have said their better than average.  You may have to send it in to them or they may just send you a replacement decoder.</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Donald Macwhirter		</title>
		<link>https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55793</link>

		<dc:creator><![CDATA[Donald Macwhirter]]></dc:creator>
		<pubDate>Wed, 15 Dec 2021 10:56:24 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=6366#comment-55793</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55781&quot;&gt;Hervey&lt;/a&gt;.

Hello Hervey,
thanks for your reply.i have e-mailed Broadway some time ago and they were very helpful,however there reset suggestion did not fix the issue.Ron Marsh from Rons train and things on you tube had the same issue and he suggested changing the settings to same as you suggested however there is no change to the problem.
i belong to the Waverley Model railway club in Melbourne Australia and we have a very large professionally wired layout.all the other locos i have including other Broadway,Kato,Atlas, Athearn etc.all run fine.so it is a bit of a mystery.

regards

Don]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55781">Hervey</a>.</p>
<p>Hello Hervey,<br />
thanks for your reply.i have e-mailed Broadway some time ago and they were very helpful,however there reset suggestion did not fix the issue.Ron Marsh from Rons train and things on you tube had the same issue and he suggested changing the settings to same as you suggested however there is no change to the problem.<br />
i belong to the Waverley Model railway club in Melbourne Australia and we have a very large professionally wired layout.all the other locos i have including other Broadway,Kato,Atlas, Athearn etc.all run fine.so it is a bit of a mystery.</p>
<p>regards</p>
<p>Don</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Donald Macwhirter		</title>
		<link>https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55792</link>

		<dc:creator><![CDATA[Donald Macwhirter]]></dc:creator>
		<pubDate>Wed, 15 Dec 2021 10:46:57 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=6366#comment-55792</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55770&quot;&gt;Andrew Brown&lt;/a&gt;.

Hello Andrew,
it would appear the track voltage is fine, we have other Broadway,Kato,Atlas Dapol locos etc and all run fine ,all my other locos run fine including a couple of other Broadway locos.
i am a member of the Waverley Model railway club in Melbourne Australia.
thanks for the reply and suggestion.
regards

Don]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55770">Andrew Brown</a>.</p>
<p>Hello Andrew,<br />
it would appear the track voltage is fine, we have other Broadway,Kato,Atlas Dapol locos etc and all run fine ,all my other locos run fine including a couple of other Broadway locos.<br />
i am a member of the Waverley Model railway club in Melbourne Australia.<br />
thanks for the reply and suggestion.<br />
regards</p>
<p>Don</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: The N-Scale Nerd		</title>
		<link>https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55791</link>

		<dc:creator><![CDATA[The N-Scale Nerd]]></dc:creator>
		<pubDate>Wed, 15 Dec 2021 09:36:12 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=6366#comment-55791</guid>

					<description><![CDATA[There&#039;s no fluff or gunk in the running gear of the trucks?]]></description>
			<content:encoded><![CDATA[<p>There&#8217;s no fluff or gunk in the running gear of the trucks?</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Hervey		</title>
		<link>https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55781</link>

		<dc:creator><![CDATA[Hervey]]></dc:creator>
		<pubDate>Wed, 15 Dec 2021 01:44:41 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=6366#comment-55781</guid>

					<description><![CDATA[Don
One power supply should not be limiting your locos if you have a &quot;Bus&quot; wire and feeds at every 6 feet and you are not running numerous (10+) locos at the same time. 
Is the slow movement only with your 3 BLI locos? If so then proceed to the decoder CV&#039;s. There are 3 CV&#039;s you want to check. First CV2 should be a low number 1 to 3, this is the voltage required to initiate movement. CV5 is the High voltage, from the factory this is a value of 255 verify that it hasn&#039;t changed and if it has set it back to 255. Once you get the loco rolling properly you can reduce the top speed by reducing this value. 
CV6 is the mid-speed value and will determine the shape of your speed curve. It can be any value you want as long as it is more than CV2 and less than CV6. To start the trial put 75 as the value. If your train now moves at more than a crawl you have resolved your issue. If not, contact BLI  or look at installing another manufacturers decoder.]]></description>
			<content:encoded><![CDATA[<p>Don<br />
One power supply should not be limiting your locos if you have a &#8220;Bus&#8221; wire and feeds at every 6 feet and you are not running numerous (10+) locos at the same time.<br />
Is the slow movement only with your 3 BLI locos? If so then proceed to the decoder CV&#8217;s. There are 3 CV&#8217;s you want to check. First CV2 should be a low number 1 to 3, this is the voltage required to initiate movement. CV5 is the High voltage, from the factory this is a value of 255 verify that it hasn&#8217;t changed and if it has set it back to 255. Once you get the loco rolling properly you can reduce the top speed by reducing this value.<br />
CV6 is the mid-speed value and will determine the shape of your speed curve. It can be any value you want as long as it is more than CV2 and less than CV6. To start the trial put 75 as the value. If your train now moves at more than a crawl you have resolved your issue. If not, contact BLI  or look at installing another manufacturers decoder.</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Doc		</title>
		<link>https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55771</link>

		<dc:creator><![CDATA[Doc]]></dc:creator>
		<pubDate>Wed, 15 Dec 2021 00:30:44 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=6366#comment-55771</guid>

					<description><![CDATA[Reset the decoder to factory setting. Cv 8 to 8. And change the address to the desired address. Then check cv,s 3 thru 6 to confirm they are at factory defaults.]]></description>
			<content:encoded><![CDATA[<p>Reset the decoder to factory setting. Cv 8 to 8. And change the address to the desired address. Then check cv,s 3 thru 6 to confirm they are at factory defaults.</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Andrew Brown		</title>
		<link>https://blog.model-train-help.com/2021/12/broadway-ge-es44ac.html#comment-55770</link>

		<dc:creator><![CDATA[Andrew Brown]]></dc:creator>
		<pubDate>Wed, 15 Dec 2021 00:25:41 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=6366#comment-55770</guid>

					<description><![CDATA[You may consider checking the track voltage, if the layout is large and you only have one power supply that could be the issue.]]></description>
			<content:encoded><![CDATA[<p>You may consider checking the track voltage, if the layout is large and you only have one power supply that could be the issue.</p>
]]></content:encoded>
		
			</item>
	</channel>
</rss>
