<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	
	>
<channel>
	<title>
	Comments on: Starting Voltage vs. CV2	</title>
	<atom:link href="https://blog.model-train-help.com/2022/01/starting-voltage-vs-cv2.html/feed" rel="self" type="application/rss+xml" />
	<link>https://blog.model-train-help.com/2022/01/starting-voltage-vs-cv2.html?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=starting-voltage-vs-cv2</link>
	<description>Model railroads and model trains</description>
	<lastBuildDate>Thu, 20 Jan 2022 13:11:31 +0000</lastBuildDate>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>
	<item>
		<title>
		By: Clif		</title>
		<link>https://blog.model-train-help.com/2022/01/starting-voltage-vs-cv2.html#comment-56423</link>

		<dc:creator><![CDATA[Clif]]></dc:creator>
		<pubDate>Thu, 20 Jan 2022 13:11:31 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=6417#comment-56423</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://blog.model-train-help.com/2022/01/starting-voltage-vs-cv2.html#comment-56417&quot;&gt;Hervey&lt;/a&gt;.

First of all, thanks for your timely response. One other question. My MCR Prodigy Advanced 2 asks for a  SV and then later on asks for CV2. Are they the same? Sorry to bother you, but would appreciate clarification. Thanks in advance. Clif]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://blog.model-train-help.com/2022/01/starting-voltage-vs-cv2.html#comment-56417">Hervey</a>.</p>
<p>First of all, thanks for your timely response. One other question. My MCR Prodigy Advanced 2 asks for a  SV and then later on asks for CV2. Are they the same? Sorry to bother you, but would appreciate clarification. Thanks in advance. Clif</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Hervey		</title>
		<link>https://blog.model-train-help.com/2022/01/starting-voltage-vs-cv2.html#comment-56417</link>

		<dc:creator><![CDATA[Hervey]]></dc:creator>
		<pubDate>Thu, 20 Jan 2022 05:07:30 +0000</pubDate>
		<guid isPermaLink="false">http://blog.model-train-help.com/?p=6417#comment-56417</guid>

					<description><![CDATA[CV 2 sets the starting voltage for the decoder. Generally a low number. It also determines the start of the speed curve. That is useful when you are trying to speed match 2 or more locos.
CV 5 is the maximum voltage the decoder will supply to the motor. (FYI it isn&#039;t actual volts but pulses but for the sake of this I will call it voltage). It is the value that sets the maximum speed of the loco and must be greater than CV6. When you plot C Vs 2, 6, and 5 on a graph of speed step as the X axis and motor power as the Y axis the resulting line (curve) is your speed curve.
CV2 determines when the motor starts to turn. CV 6 determines what speed the loco will move at at mid throttle. CV 5 determines loco speed at maximum throttle.]]></description>
			<content:encoded><![CDATA[<p>CV 2 sets the starting voltage for the decoder. Generally a low number. It also determines the start of the speed curve. That is useful when you are trying to speed match 2 or more locos.<br />
CV 5 is the maximum voltage the decoder will supply to the motor. (FYI it isn&#8217;t actual volts but pulses but for the sake of this I will call it voltage). It is the value that sets the maximum speed of the loco and must be greater than CV6. When you plot C Vs 2, 6, and 5 on a graph of speed step as the X axis and motor power as the Y axis the resulting line (curve) is your speed curve.<br />
CV2 determines when the motor starts to turn. CV 6 determines what speed the loco will move at at mid throttle. CV 5 determines loco speed at maximum throttle.</p>
]]></content:encoded>
		